Fire door FRD III
Single- and double-leaf steel fire doors for interior use with load class C4.

FRD III · Interior fire door, class C4
- EI 15–60 DP1
- EW 15–60 DP1
- EW 90 — double-leaf version
The FRD III fire closure is designed for interior openings in residential and industrial construction. The structure consists of a steel profile with an insulation core and a 0.8 mm steel sheet skin. In load testing the door was classified as C4 — high frequency of use by the public with little maintenance motivation.
Technical data
- Category
- Steel doorsFire doors
- Design
- Single leafDouble leaf
- Fire resistance
- EI 15EI 30EW 15EW 30
- Smoke tightness
- Sa/Sm
- Security class
- No
- Cycle resistance
- C5
- Environment
- Interior
- Heat transfer
- 1,7 W/m²K
- Application
- Public buildingsIndustry
- ATEX
- Zone 0-2
Application
- Interior openings, residential and industrial construction
- High reliability under frequent use
Fire resistance
- EI 15–60 DP1
- EW 15–60 DP1
- EW 90 — double-leaf version
Design
- Single-leaf up to 1100 × 2500 mm
- Double-leaf up to 2500 × 2500 mm
- Hinges TKZ Polná ZD 80/10 M10×50 VD ZN
- Ventilation grille (EI 15; EW 15–90)
- Glazing 1/3, 2/3 or 3/3 of the leaf area
- Smoke-tight execution
- Insulation U = 1.7 W/m²K
- Acoustic insulation Rw = 38 dB (double-leaf 40 dB)
Finish
- Galvanised steel — standard
- RAL colour coating
- Stainless steel
Frame
- Into a standard frame
- Into a sealed frame
Equipment options
- Security hardware
- Panic hardware
- Door closer
- Automatic threshold
- Holding magnet
Summary
Product configurator
Choose the design — the datasheet is generated for your configuration.
Loading options…